lt is effective to protect the original bare power equipment connect terminate from the power turnoff and electric shock, which is caused by the reasons such as persona contact, stolen power, small animal or other things contact, moist flash salt fog and chemical corruption.As so big economic damage can be avoided.
Order code | Name of the assembled fitting | Connecting type | Numbers of the conductor x specification |
B001 | Zinc oxide lightning arrester | the lateral | 1x35²~240² |
DB01 | Zinc oxide lightning arrester | the lateral | 1x35²~240² |
B002 | Zinc oxide lightning arrester | the lateral | 1x35²~240² |
G002 | Transformerhigh voltageterminalhorizontaloutlet | the lateral | 1x35²~240² |
D007 | Transformerlow voltage terminalhorizontaloutlet | the lateral | 1x35²~240² |
D008T | Transformerlow voltage terminalhorizontaloutlet 100# | the lateral | Applicable to busbar 100x10 (within) |
Note: Special specifications can be produced according to the requirements of clients.
Order code | Name of the assembled fitting | Connecting type | Numbers of the conductor × specification |
G005 | Transformerhigh voltage terminalhorizontaloutlet | the lateral | 1×352~2402 |
G004 | Transformer high voltage equipment clamp horizontaloutputline 1# 2# | the lateral | 1×352~2402 |
G004D | Transformer high voltage equipment clamp horizontaloutputline 3# 4# | the lateral | 1×352~2402 |
G003 | Transformer high voltage equipment clamp 30 degree outlet 1#2# | oblique | 1×352~2402 |
D009 | Transformerlow voltage equipment clamp horizontaloutlet 1# 2# | the lateral | 1×352~2402 |
D019 | Transformer low voltage equipment clamp horizontaloutlet3# 4# | the lateral | 1×352~2402 |
D05 | Transformerlow voltage equipment clamp 30 degree outlet 1#2# | oblique | 1×352~2402 |
D005 | Transformerlow voltage equipment clamp 30 degree outlet 3#4# | oblique | 1×352~2402 |
G007 | Transformer high voltage pole clamp line M22 | oblique | 1×352~240 |
D013A | Transformerlow voltage pole clamp line outlet M28 | oblique | 1×352~2402 |
D013 | Transformerlowvoltage pole clamp line outlet M22 | oblique | 1×352~2402 |
D002 | Transformerlow voltage busbarverticaloutgoing line 80# | vertical | Applicable to busbar 80x8 (within) |
D002T | Transformerlow voltage busbarverticaloutgoing line 100# | vertical | Applicable to busbar 100x10 (within) |
Order code | Matching device name |
JX-3 | Measuring box three-columnjacket 3# |
JX-2 | Measuring box three-columnjacket2# |
SLG | Equipment line clamp sheath 1# 2# 3# 4# |
RW7 | RW7 drop switch housing |
GW9 | GW9 isolation switchjacket |
NLD tension clamp guard | NLD tensile clamp cover 1# 2# 3# 4# |
C-type cable clamp guard | Ctype clamp cover1# 3# 5# |
JB parallel groove cable clamp shield | JB Ditch lineclamp1# 2# 3# 4# |
RW12 | RW12 drop switch housing |
DLB001 | Removable arrester sheath |
S&C Shield | S&clsolation switch guard |
ZW32G | ZW32 with isolation vacuum switch |
RW11 | RW11/10 cascade switches |
H25 | Cable head sheath |